Rare central venous catheter malposition – an ultrasound-guided approach would be helpful: a case report

Abstract

Background

A central venous catheter enables the measurement of hemodynamic variations, such as accurate central venous pressure; catheter malposition may induce potentially fatal complications. This case report describes a rare central venous catheter tip malposition in the right internal mammary artery.

Case presentation

A 56-year-old Japanese woman who presented with severe pneumonia secondary to scleroderma was treated under ventilator support because of acute respiratory failure. A right central venous catheter was inserted using a landmark technique to monitor central venous pressure and administer medications. However, central venous waveforms detected by the catheter using a pressure lot transducer were later found to be absent. Further imaging studies, including plain radiography, computed tomography, and angiography, confirmed central venous catheter malposition in the internal mammary artery. Her right internal mammary artery was embolized using two interlocking detachable coils, and the central venous catheter was removed from her internal mammary artery without further complications.

Conclusions

Internal mammary artery malposition is a rare but potentially lethal complication of central venous catheter catheterization; however, caution should be taken regarding the assessment of risk factors and management of a severe complication. An ultrasound-guided approach would be helpful.

Peer Review reports

Background

A central venous catheter (CVC) enables the measurement of hemodynamic variations, including accurate measurement of central venous pressure (CVP), as well as delivery of medications and nutritional support. Numerous complications of central venous catheterization have been reported, including malposition, arterial puncture, hematoma, pneumothorax, hemothorax, infection, and thrombosis. Catheter malposition may result in severe complications [1]. We report a rare case of a CVC tip malpositioned in the right internal mammary artery (IMA).

Case presentation

A 56-year-old Japanese woman who presented with severe pneumonia secondary to scleroderma was treated under ventilator support because of acute respiratory failure. A physical examination revealed fever with a body temperature of 100.7 °F (38.2 °C), tachypnea with a respiratory rate of 25 breaths/minute, blood pressure of 127/67 mmHg, pulse 120 beats/minute, and level of consciousness was normal. Arterial blood gas analysis revealed pH 7.419, partial pressure of carbon dioxide in arterial blood (PaCO2) 55.9 mmHg, partial pressure of oxygen in arterial blood (PaO2) 64.5 mmHg, and bicarbonate (HCO3 -) 40.9 mmol/L. A laboratory test revealed the following data: leukocytosis at 20.6×10−3/μL, hemoglobin level of 8.5 g/dL, platelet count of 331×10−3/μL, an international normalized ratio (INR) of 1.64, serum creatinine level of 0.18 mg/dL, C-reactive protein level of 23.44 mg/dL, serum gamma-glutamyltransferase level of 139 IU/L, alkaline phosphatase level of 618 IU/L, and total bilirubin of 0.4 mg/dL. She had no prior relevant medical or surgical history.

A right CVC was inserted using a landmark technique to monitor CVP and administer medications. A double lumen 16 G catheter was inserted by an experienced internal physician using the Seldinger technique. With this approach, a resistance to guidewire advancement was met at a depth of 7 cm, but it was advanced further without resistance. CVC was fixed at 13 cm at the skin level, after free aspiration of blood. Continuous infusion of normal saline through CVC was initiated using an infusion pump. CVP and arterial waveforms were not observed following connection of the catheter to a pressure kit transducer. A chest X-ray was immediately arranged to confirm the catheter position (Fig. 1). The catheter was found to have descended lateral to the right mediastinal margin without signs of either pneumothorax or pleural effusion. Thoracic computed tomography findings were suggestive of CVC malposition in her right IMA (Fig. 1). An angiography performed using CVC confirmed the malposition in her right IMA (Fig. 2 left). Selective right subclavian and right internal angiographies were performed with consideration of the injury to her right subclavian artery. Subsequently, embolization of her right IMA was performed with two interlocking detachable coils (IDC; Boston Scientific Japan, Tokyo, Japan). After coil embolization, her right IMA was occluded before successful removal of the catheter without further complications, such as acute bleeding (Fig. 2 right). A few days later, she developed acute respiratory distress syndrome, and she died on the seventh day of intensive care unit (ICU) admission.

Fig. 1
figure 1

Chest X–ray revealing a CVC descending lateral to the mediastinal margin (left arrow). Thoracic computed tomography demonstrated CVC malpositioning in the right IMA (right arrow)

Fig. 2
figure 2

Right branchiocephalic arteriography revealing catheter placement in the right internal mammary artery (left arrow). Right internal mammary artery occlusion following coil embolization (right arrow)

Discussion

Catheter malpositioning may result in potentially fatal complications. The incidence of catheter malposition has been reported to be between 5 and 12 % [2]. In a large prospective study by Pikwer et al. of 1619 central line catheterizations [3], using the landmark technique, cannulation by the right subclavian vein was associated with the highest risk of malposition, 9.1 %, compared with 1.4 % by the right internal jugular vein. There have been a number of previous reports of CVC malpositioning in the internal mammary vein [48]. However, IMA malpositioning is extremely rare with only a few reports of this complication, all involving an inadvertent puncture of IMA [911]. Puncture of IMA may induce mediastinal or pleural hematoma, pseudoaneurysm, or arteriovenous fistula. Arterial bleeding can take a dramatic course with severe bleeding inducing hemomediastinum or hemothorax, thus requiring immediate treatment. In this case, no signs of inadvertent arterial puncture of IMA were observed; however, the possibility for massive bleeding occurred when the malpositioned catheter was removed. The mechanism of IMA malpositioning is unclear. The bevel orientation facilitates the progression of the guidewire in the intended direction; incorrect venipuncture positioning may have caused catheter insertion inferior to the recommended site (Fig. 3 left). The catheter was directly inserted into IMA without injury to the subclavian artery (Fig. 3 right). Catheter malpositioning was adequately demonstrated by selective angiography, with subsequent embolization leading to a satisfactory result. The micro-catheter system allowed selective catheterization and embolization of IMA. Transarterial embolization with microcoils is an efficient technique for the treatment of catheter malpositioning.

Fig. 3
figure 3

Schematic depiction of the anatomy of the right internal mammary artery in relation to the right subclavian artery and the internal artery (right). The mechanism of the malposition is not entirely clear. It is possible that the catheter was inserted too proximally to the optimal insertion site (left) so that it was directly inserted into the internal mammary artery (right, arrow). Rt. right

This case highlights the importance of CVP waveform monitoring and chest X-ray in ensuring correct catheter placement, particularly in unconscious or intubated patients in intensive care settings. CVP waveform could not be obtained, which strongly indicated the possibility of misplacement of CVC despite free aspiration of blood. Therefore, pressure waveform monitoring and checking and acting on chest X-ray after central catheter placement may be used to prevent accidental arterial cannulation. Catheter malpositioning occurred in this case despite cannulation being performed by an experienced internal physician. The experience of the physician inserting a CVC is of paramount importance. The risk of mechanical complications increases significantly if the doctor performing the procedure has inserted less than 50 CVCs [12]. Simulation training and use of ultrasound guidance were associated with improved in-hospital performance of CVC insertion [13]. Ultrasound guidance, in addition to direct visualization, when placing venous catheters has been shown to reduce the incidence of complications and is useful in identifying diminutive or thrombosed vessels [14]. Ultrasound guidance has previously been recommended for all CVC procedures [15]. IMA malposition is a rare but potentially lethal complication of CVC that should be considered in risk factor assessments and the management of severe complications resulting from CVC.

Conclusions

We present a rare case of CVC malpositioning in the right IMA. Awareness of the possibility of this rare complication and early angiographic intervention may avoid further complications. Therefore, one must consider the possibility of incorrect placement of the catheter. Monitoring the central venous wave form and obtaining chest X-rays can be useful methods to confirm the position of the catheter. An ultrasound-guided approach rather than the use of a landmark technique to insert CVC will help. Ultrasound guidance is important to minimize the risk of malposition.

Abbreviations

CVC:

Central venous catheter

CVP:

Central venous pressure

IMA:

Internal mammary artery

References

  1. Ghatak T, Azim A, Baronia AK, Muzaffar SN. Malposition of central venous catheter in a small tributary of left brachiocephalic vein. J Emerg Trauma Shock. 2011;4(4):523–5.

    PubMed  PubMed Central  Google Scholar 

  2. Schummer W, Schummer C, Rose N, Niesen WD, Sakka SG. Mechanical complications and malpositions of central venous cannulations by experienced operators. A prospective study of 1794 catheterizations in critically ill patients. Intensive Care Med. 2007;33(6):1055–9.

    Article  PubMed  Google Scholar 

  3. Pikwer A, Bååth L, Davidson B, Perstoft I, Akeson J. The incidence and risk of central venous catheter malpositioning: a prospective cohort study in 1619 patients. Anaesth Intensive Care. 2008;36(1):30–7.

    CAS  PubMed  Google Scholar 

  4. Abbott G, Evans P. Therapeutic embolization of an internal mammary artery damaged by placement of a central venous catheter. Br J Anaesth. 2001;86(1):143–5.

    Article  CAS  PubMed  Google Scholar 

  5. Mazeh H, Alaiyan B, Vald O, Mizrahi I, Klimov A, Eid A, Freund HR. Internal mammary artery injury during central venous catheter insertion for TPN: rare but fatal. Nutrition. 2010;26(7-8):849–51.

    Article  PubMed  Google Scholar 

  6. Liao HR, Li TS, Chen KB, Li CY, Jeng LB, Yang HR, Poon KS. Rare malposition of a central venous catheter into the left internal mammary vein in a liver transplantation patient. J Anesth. 2011;25(3):462–4.

    Article  PubMed  Google Scholar 

  7. Moeinipour AA, Amouzeshi A, Joudi M, Fathi M, Jahanbakhsh S, Hafez S, Izanloo A, Khorsand M. A rare central venous catheter malposition: a case report. Anesth Pain Med. 2014;4(1):e16049.

    PubMed  PubMed Central  Google Scholar 

  8. Kanter G, Connelly NR. Unusual positioning of a central venous catheter. J Clin Anesth. 2005;17(4):293–5.

    Article  PubMed  Google Scholar 

  9. Chemelli AP, Chemelli-Steingruber IE, Bonaros N, Luckner G, Millonig G, Seppi K, Lottersberger C, Jaschke W. Coil embolization of internal mammary artery injured during central vein catheter and cardiac pacemaker lead insertion. Eur J Radiol. 2009;71(2):269–74.

    Article  CAS  PubMed  Google Scholar 

  10. Chou TM, Chair KM, Jim MH, Boncutter A, Milechman G. Acute occlusion of left internal mammary artery graft during dual-chamber pacemaker implantation. Catheter Cardiovasc Interv. 2000;51(1):65–8.

    Article  CAS  PubMed  Google Scholar 

  11. Hama Y, Kaji T, Fujii M, Kosuda S. Internal mammary artery injury following subclavian vein catheterization. Emerg Radiol. 2005;11(3):170–2.

    Article  PubMed  Google Scholar 

  12. Polderman KH, Girbes AJ. Central venous catheter use. Part 1: mechanical complications. Intensive Care Med. 2002;28(1):1–17.

    Article  PubMed  Google Scholar 

  13. Evans LV, Dodge KL, Shah TD, Kaplan LJ, Siegel MD, Moore CL, Hamann CJ, Lin Z, D’Onofrio G. Simulation training in central venous catheter insertion: improved performance in clinical practice. Acad Med. 2010;85(9):1462–9.

    Article  PubMed  Google Scholar 

  14. Teichgraber UKM, Benter T, Gebel M, Manns M. A sonographically guided technique for central venous access. Am J Roentgenol. 1997;169:731–3.

    Article  CAS  Google Scholar 

  15. Stone MB, Nagdev A, Murphy MC, Sisson CA. Ultrasound detection of guidewire position during central venous catheterization. Am J Emerg Med. 2010;28(1):82–4.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank David who provided medical writing services on behalf of Crimson Interactive Pvt. Ltd.

Funding source

No funding was secured for this study.

Authors’ contributions

All authors were involved in patient care at bedside. All authors read and approved the manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Written informed consent was obtained from the patient's next of kin for the publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Keisuke Kumada.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kumada, K., Murakami, N., Okada, H. et al. Rare central venous catheter malposition – an ultrasound-guided approach would be helpful: a case report. J Med Case Reports 10, 248 (2016). https://doi.org/10.1186/s13256-016-1026-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13256-016-1026-0

Keywords