Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report

Abstract

Background

Patella fractures represent 1 % of all musculoskeletal system fractures. Fixation of patellar fractures using open reduction and tension band wiring is a commonly used and successful surgical fixation method.

Case presentation

A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin on the dorsolateral side of his right foot. Except for the palpable and moving body of about 6 cm length under the skin in his foot, he had no functional complaints. On X-ray, a Kirschner wire was visible in front of the lateral malleolus on the dorsolateral side of his right foot. In addition, there was a cerclage wire from the tension band fixation of his patella in the ipsilateral knee. The Kirschner wire was removed surgically.

Conclusion

Despite the use of different fixation materials for the surgical treatment of patellar fractures, tension band wiring is still a commonly used technique. We recommend that after fixation of a patellar fracture using the tension band wiring technique, the ends of the Kirschner wires be bent and the wires then removed in the early phase after patellar union to prevent Kirschner wire migration.

Peer Review reports

Background

Patella fractures represent 1 % of all musculoskeletal system fractures [1]. Most injuries caused by indirect trauma occur in the middle third part of the patella. Conservative treatment is carried out more frequently in patients with no incompatibility on the articular surface. Surgical treatment is performed in patients with 2–3 mm of articular displacement [2].

Arbeitsgemeinschaft für Osteosynthesefragen (AO)-modified tension band wiring is used in the treatment of fractures such as malleolus fractures, olecranon fractures, and transverse patella fractures [35]. Fixation of patellar fractures with open reduction and tension band wiring is a successful surgical fixation method commonly used today. Successful fixation can be achieved particularly in split patellar fractures. However, there may be Kirschner (K)-wire migration after fixation; to prevent this, the ends of the K-wire are generally bent and then the wires removed in the early phase after bone union [6]. Patellar fractures are frequently successfully treated using tension band wiring, and migration of the K-wire, as in our case, is limited. We believe this is the first report of pin migration to the dorsolateral side of the foot.

Case presentation

A 28-year-old male patient from Turkey presented to our clinic with complaints of palpable foreign bodies under the skin in the dorsolateral side of his right foot (Fig. 1). Except for the palpable and moving body of about 6 cm length under the skin in his foot, he had no functional complaints. An X-ray demonstrated the presence of a K-wire of about 6 cm length in front of the lateral malleolus in the dorsolateral side of his foot (Fig. 2). There was a cerclage wire from the tension band fixation of his patella in the ipsilateral knee (Fig. 3). There was no diagnostic challenge. Our patient explained that he was operated on by another orthopedic surgeon in the same hospital after a patellar fracture in 2007 and he had not attended regular checks. He also reported that a wire similar to the one in the X-ray had protruded through his skin in 2009 and he had removed the wire by pulling it out. This statement explained why the K-wire was not in place.

Fig. 1
figure 1

Palpable foreign body under the skin on the dorsolateral side of the right foot

Fig. 2
figure 2

Anteroposterior plain radiography showing a Kirschner wire in the dorsolateral side of the right foot

Fig. 3
figure 3

Anteroposterior plain radiography showing a cerclage wire from the tension band fixation of the patella of the ipsilateral knee

On physical examination, our patient showed no restriction in his knee movement. Routine blood test results showed no abnormalities. Palpation of the K-wire showed that the wire was mobile under his skin (Fig. 1). Our patient reported that, after removing the first wire, he had not felt any serious discomfort during the migration of the other wire over a period of 5 years.

Our patient was taken to the operating room. After staining, a 3-mm skin incision was made that coincided with the proximal end of the K-wire, and the K-wire was pulled out with the help of clamp (Fig. 4). Our patient was discharged on the same day. The cerclage wire in his patella was not removed to avoid creating complications and because of our patient’s unwillingness to have it removed.

Fig. 4
figure 4

The Kirschner wire was pulled out with the help of a clamp

Discussion

Despite the use of different fixation materials for the surgical treatment of patellar fractures, the tension band wiring technique is today still a commonly used method [7, 8]. Although a successful treatment option, if the ends of the K-wires are not bent after the operation and then removed in the early phase following bone union, wire breakages and various degrees of migration can be observed. Migrations in the popliteal and proximal anterior tibia after fixation of the patella using tension band wiring have been reported in the literature [7, 8]. Indeed, K-wire migrations have been reported after the fixation of fractures and dislocations in various regions. Longitudinal and lung migrations of the wire after the fixation of acromioclavicular and clavicle fractures are among the most frequently reported cases after migration following proximal humeral fracture fixation [9, 10]. Similarly, wire migration to the pelvis is among the complications reported after temporary transacetabular K-wire fixation to prevent dislocation during the cast winding process in developmental dysplasia of the hip [11]. It is possible for small, unnoticed wire fragments to remain in the tissue following wire removal and to be carried to distant regions, especially to the heart, after they penetrate the blood vessels [12]. Failure of hardware after pin migration is a well-known complication. Additionally, K-wires often break when retained for a long period after fracture union. Owing to their inherently smooth nature, K-wires are prone to migrate. Because they are thin, un-threaded, and tubular, K-wires have a strong tendency to migrate along the paths of least resistance. To prevent this, pins should be bent and left outside the skin in the majority of the patients [7]. We found few statistics in the literature about pin migration, although several literature reviews have been published, such as Lyons and Rockwood in 1990 (47 cases) [13], Freund et al. in 2007 (68 cases) [14], Sarma et al. in 2007 (four cases) [15], and Guèye et al. in 2015 (three cases) [16], suggesting that the number of cases of this complication is growing all over the world.

The migration of a K-wire from the patella to the dorsolateral side of the foot, as presented in this case, has not previously been reported in the literature. In our case, it is interesting that the K-wire was able to migrate to our patient’s foot without causing any symptoms or any additional complications.

Conclusion

K-wires can easily migrate, which may result in significant complications. We recommend that the ends of the wires be bent, and the wires removed in the early phase after bone union to prevent K-wire migration following the fixation of a patellar fracture using the tension band wiring technique.

Consent

Written informed consent was obtained from the patient for publication of this case report and accompanying images. A copy of the written consent is available for review by the Editor-in-Chief of this journal.

References

  1. Lotke PA, Ecker ML. Transverse fractures of the patella. Clin Orthop Relat Res. 1981;158:180–4.

    Google Scholar 

  2. Appel MH, Seigel H. Treatment of transverse fractures of the patella by arthroscopic percutaneous pinning. Arthroscopy. 1993;9:119–21.

    Article  CAS  PubMed  Google Scholar 

  3. Doursounian L, Prevot O, Touzard RC. Osteosynthesis by tension band wiring of displaced fractures of the olecranon. Ann Chir. 1994;48:169–77.

    CAS  PubMed  Google Scholar 

  4. Fan GF, Wu CC, Shin CH. Olecranon fractures treated with tension band wiring techniques – comparisons among three different configurations. Chang Gung Med J. 1993;16:231–8.

    CAS  Google Scholar 

  5. Levack B, Flannagan JP, Hobbs S. Results of surgical treatment of patellar fractures. J Bone Joint Surg. 1985;67:416–9.

    CAS  Google Scholar 

  6. Kınık H, Us AK, Mergen E. Self-locking tension band technique: a new perspective in tension band wiring. Arch Orthop Trauma Surg. 1999;119:432–4.

    Article  PubMed  Google Scholar 

  7. Meena S, Nag HL, Kumar S, Borwar N. Delayed migration of K-wire into popliteal fossa used for tension band wiring of patellar fracture. Chin J Traumatol. 2013;16(3):186–8.

    PubMed  Google Scholar 

  8. Konda SR, Dayan A, Egol KA. Progressive migration of broken Kirschner wire into the proximal tibia following tension-band wiring technique of a patellar fracture--case report. Bull NYU Hosp Jt Dis. 2012;70(4):279–82.

    PubMed  Google Scholar 

  9. Karaman I, Kafadar IH, Oner M, Halici M. Intrapelvic pin migration after Salter innominate osteotomy and laparoscopic removal: a case report. J Pediatr Orthop B. 2013;22(6):553–5.

    Article  Google Scholar 

  10. Yadav V, Marya KM. Unusual migration of a wire from shoulder to neck. Indian J Med Sci. 2003;57(3):111–2.

    CAS  PubMed  Google Scholar 

  11. Yurtçu M, Şenaran H, Türk HH, Abasıyanık A, Tuncay İ. Migration of intra-articular K-wire into the controlateral pelvis after surgery for developmental dysplasia of the hip: a case report. Acta Orthop Traumatol Turc. 2010;44(5):413–5.

    Article  PubMed  Google Scholar 

  12. Sepicel RC, Schmeling GJ, Deley RA. Migration of a K-wire from the distal radius to the heart. Am J Orthop. 2001;30(2):147–51.

    Google Scholar 

  13. Lyons FA, Rockwood Jr CA. Migration of pins used in operations on the shoulder. J Bone Joint Surg. 1990;72:1262–7.

    Article  CAS  PubMed  Google Scholar 

  14. Freund E, Nachman R, Gips H, Hiss J. Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade: case report and review of literature. Am J Forensic Med Pathol. 2007;28:155–6.

    Article  CAS  PubMed  Google Scholar 

  15. Sharma H, Taylor GR, Clarke NM. A review of K-wire related complications in the emergency management of paediatric upper extremity trauma. Ann R Coll Surg Engl. 2007;89(3):252–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  16. Guèye ML, Thiam O, Touré AO, Seck M, Cissé M, Kâ O, et al. Migration of guide pin in pelvic surgery in hip fractures: about 3 cases. Pan Afr Med J. 2015;21:112.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We thank our patient, who provided us with the opportunity to report this rare and valuable medical experience.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Turan Cihan Dülgeroğlu.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

TCD, HM, and EA contributed equally to this work. EA cared for the patient, including surgery and follow-up, and obtained consent from the patient. TCD wrote the initial draft and helped revise the manuscript. HM drafted and revised the manuscript and assessed the quality of the paper. All authors read and approved the final manuscript.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Aydın, E., Dülgeroğlu, T.C. & Metineren, H. Migration of a Kirschner wire to the dorsolateral side of the foot following osteosynthesis of a patella fracture with tension band wiring: a case report. J Med Case Reports 10, 41 (2016). https://doi.org/10.1186/s13256-016-0819-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13256-016-0819-5

Keywords