Skip to main content

Table 1 Laboratory data on admission

From: Cold agglutinin-induced hemolytic anemia during room temperature fluid resuscitation: a case report

Laboratory parameters Patient’s values Reference range
White blood cell (cells/μL) 25,800 3300–8600
Hemoglobin (g/dL) 9.1 13.7–16.8
MCV (fL) 112 83.6–98.2
Platelets (cells/μL) 291,000 158,000–340,000
Sodium (mmol/L) 135 138–145
Potassium (mmol/L) 5.1 3.6–4.8
Chloride (mmol/L) 102 101–108
Urea nitrogen (mg/dL) 60.2 8–20
Creatinine (mg/dL) 1.48 0.65–1.07
C-reactive protein (mg/dL) 4.42 <0.14
AST (IU/L) 55 13–30
ALT (IU/L) 30 10–42
LDH (IU/L) 526 124–222
Total bilirubin (mg/dL) 1.2 0.4–1.5
Glucose (mg/dL) 710 73–109
ABG: pH 6.723 7.35–7.45
ABG: bicarbonate (mmol/L) 2.2 21–27
Urine acetone body 3+  
  1. MCV Mean corpuscular volume, AST aspartate aminotransferase, ALT alanine aminotransferase, LDH lactate dehydrogenase, ABG arterial blood gas