Skip to main content

Table 1 Profile three-dimensional full-volume Color Doppler of echocardiographic results. The last three rows are the de-aliased mitral inflow, left ventricular outflow, and mitral regurgitation volumes based on the sampled volumetric color Doppler data by three-dimensional full-volume color Doppler transthoracic echocardiography

From: Combined flow-based imaging assessment of optimal cardiac resynchronization therapy pacing vector: a case report

  Acute study (13-day follow-up) Acute study (13-day follow-up) Acute study (6-month follow-up)
Mean value measure (ml) CRT OFF CRT ON
VV delay 0 ms
CRT ON
VV delay − 50 ms
Three-dimensional full-volume color Doppler transthoracic echocardiography: mitral inflow volume 100.3 83.2 62.4
Three-dimensional full-volume color Doppler transthoracic echocardiography left ventricular outflow: outflow volume 35 21.6 104.7
Three-dimensional full-volume color Doppler transthoracic echocardiography: mitral regurgitation volume 65.3 61.6 42.2
  1. CRT cardiac resynchronization therapy, VV interventricular